POINT G UV LED Lash Lamp: Every Safety Test, Explained
Share
Here's exactly what our POINT G UV LED lash lamp was tested for, who tested it and what the results were, including the ones that need a little explaining.
This guide lists every test completed on the POINT G lamp series and explains what each one means for you and your clients.
POINT G test summary
All testing was commissioned by our manufacturer and carried out by independent third-party laboratories in 2023.
| Test | What it checks | Laboratory | Report no. / date | Result |
|---|---|---|---|---|
| EN 62471:2008 (IEC 62471:2006) | Photobiological safety: UV, blue light and infrared exposure to eyes and skin | Standard Technology Union (STU) | STUESO230300042LM-1 Aug 7, 2023 |
Pass, Risk Group 2 |
| EN 60598-2-4 / EN IEC 60598-1 | Electrical safety of portable luminaires: insulation, heating, construction, marking | Standard Technology Union (STU) | STUESO230700031LM Jul 21, 2023 |
Pass |
| EMC (EN IEC 55015, EN 61547, EN IEC 61000-3-2, EN 61000-3-3) | Electromagnetic compatibility: the lamp doesn't interfere with other devices and isn't disrupted by them | Standard Technology Union (STU) | STUEMO230700016LM Jul 19, 2023 |
Pass |
| FCC Part 15 (ANSI C63.4) | Electromagnetic emissions (North American requirement) | Standard Technology Union (STU) | STUEMO230700018LM Jul 19, 2023 |
Pass |
| RoHS (2011/65/EU + 2015/863) | Restricted hazardous substances such as lead, mercury and cadmium in the electronics | Eurones Consumer Products Testing | C230705047001-2 Jul 26, 2023 |
Pass |
EN 62471: what "Risk Group 2" means
EN 62471 is the European standard for the photobiological safety of lamps. It measures how much UV, blue light and infrared reaches the eye and skin at a fixed test distance of 20 cm, then places the lamp in one of four risk groups:
- Exempt (Risk Group 0): no hazard, even with long exposure
- Risk Group 1 (low risk): no hazard under normal behaviour
- Risk Group 2 (moderate risk): no hazard as long as you don't stare into the light. People naturally look away from bright light, and that response protects the eye.
- Risk Group 3 (high risk): can be hazardous even with brief exposure
POINT G is classified as Risk Group 2. It passed every requirement for that group, and no measurement came close to Risk Group 3.
Why a professional curing lamp can't be "exempt"
A UV LED lash lamp has one job: deliver enough UV-A light to cure adhesive in about 1–2 seconds. To qualify as exempt, the UV-A measured at 20 cm must stay under 10 W/m². That is far less light than UV adhesive needs to cure quickly. A floor or table stand lamp works at a similar distance to the test distance, so if it cures fast, it will measure above the exempt limit.
That's why we publish our real classification. Risk Group 2 is normal and expected for a professional curing lamp, and it is fully compliant.
The other tests, in plain language
Electrical safety (EN 60598)
This is the standard for portable lamps. It checks protection against electric shock, insulation, temperature rise, mechanical strength and correct marking. POINT G runs on low-voltage 5V DC (Class III) through its adapter, the safest electrical class for this kind of equipment.
EMC
Electromagnetic compatibility testing confirms that the lamp doesn't disrupt other electronics in your studio and keeps working normally around them.
FCC Part 15
This is the US and North American requirement that limits the electromagnetic interference electronic devices can emit.
RoHS
RoHS restricts hazardous substances such as lead, mercury, cadmium and certain flame retardants in electrical equipment.
Using POINT G safely
Testing tells you how a lamp performs under defined conditions. Safe technique is still essential:
- Keep the client's eyes fully closed and protected throughout the service.
- Aim the light only at the lash bonding area. Never look into the beam or point it at anyone's open eyes.
- Make sure every bond is 100% cured. Position the light so it reaches the whole bond, with no shadows from your tweezers, hand or neighbouring lashes blocking it. Adhesive that isn't fully cured still gives off fumes and contains allergens that can irritate your client's eyes.
- Wear the included UV400 protective goggles.
- Keep exposure brief and keep to the recommended working distance.
Frequently asked questions
Is POINT G safe to use on clients?
Yes, when used as directed. It passed EN 62471 photobiological safety testing in Risk Group 2. With the client's eyes closed and protected and the beam aimed only at the lash line, the exposure is controlled and brief.
Is any UV lash lamp "UV-free"?
No. UV LED lash adhesive cures with UV-A light, so every curing lamp emits UV. What matters is that the lamp has been properly tested and that you use it with the right precautions.
Does POINT G work with other brands' adhesives?
Yes. POINT G isn't locked to our glue: it cures UV LED lash adhesives from any brand designed for 395–400 nm, the wavelength most UV LED lash adhesives are made for. Check your adhesive's recommended wavelength before use. Regular air-cure lash glue doesn't cure with UV light.
Do I need POINT G to use Lash Atelier adhesives?
No. Our ECLIPSE and INFINITY adhesives cure with UV LED lash lamps in the 395–400 nm range, the wavelength most lash lamps use. Check your lamp's wavelength, and if you're unsure, contact us before buying.
Can I see the test documentation?
Yes. Contact us and we'll be happy to share details for professional or insurance purposes.
Shop with confidence
We believe lash artists deserve honest information about the tools they use on their clients. Explore the POINT G UV LED lash lamp →
Have questions about our testing? Email infolashatelier@gmail.com.